Q-Series High-Capacity Waste Heat Recovery Boiler Systems

Harnessing Industrial Power: The Q-Series High-Capacity Waste Heat Recovery BoilerIn the demanding environment of the modern chemical industry and large-scale manufacturing, energy...


  • Evaporation: 12~35t/h
  • Steam Pressure: 1.25~3.82MPa
  • Flue Gas Temperature: 850~950℃
  • Flue Gas Flow Rate: 40,000~130,000Nm³/h
  • Outlet Flue Gas Temperature: 194 - 450 °C

Description

Product Tags

Harnessing Industrial Power: The Q-Series High-Capacity Waste Heat Recovery Boiler

In the demanding environment of the modern chemical industry and large-scale manufacturing, energy efficiency is not just a goal—it's a cornerstone of profitability and sustainability. Our Q-Series High-Capacity Waste Heat Recovery Boiler Systems are engineered to meet this challenge head-on. By capturing and converting high-temperature flue gas into valuable high-pressure steam, these systems offer a powerful solution for reducing operational costs, minimizing environmental impact, and maximizing thermal efficiency.

Designed for robustness and performance, this series of boilers is adept at handling significant flue gas volumes ranging from 40,000 to 130,000 Nm³/h, with inlet temperatures as high as 950°C. The result is a substantial steam generation capacity of up to 35 tons per hour, making it an ideal choice for large chemical plants, refineries, and other industrial processes that produce a significant amount of waste heat.

Core Features and Technical Specifications

The design of our high-capacity Q-Series boilers incorporates advanced heat exchange surfaces, including dedicated superheaters, economizers, and air preheaters, to ensure maximum heat recovery. The modular design facilitates transportation and installation, while the robust construction guarantees long-term reliability even under continuous operation. Below are the detailed technical specifications for our primary models in this range.

ParameterQ40/850-12-1.25Q50/900-15-1.25/300Q66/800-25-1.25/300Q86/800-25-3.82/450Q130/950-35-3.82/450
Rated Evaporation Capacity (t/h)1215252535
Rated Steam Pressure (MPa)1.251.25/1.61.253.823.82
Flue Gas Flow Rate (Nm³/h)40000500006600075000130000
Inlet Flue Gas Temperature (°C)850900900900950
Outlet Flue Gas Temperature (°C)194300300450450
Main Body Heating Surface (m²)683842.5/871.7160411451961
Superheater Heating Surface (m²)/30.570.5171270
Economizer Heating Surface (m²)//7501660984
Air Preheater Heating Surface (m²)//501//
System Resistance (Pa)< 2000< 1500< 2000< 1500< 1600
Max. Transport Weight (t)38.9BulkBulkBulkBulk
Application ScopeChemical Industry

Note: The product performance and technical parameters listed are subject to change. The final specifications are based on the official technical documents provided with the product at the time of delivery.

Company Strength & Qualifications

Modern Manufacturing Factory
Quality Certifications

INQUIRY

If you want to get a quotation or more product details, please leave us a message, You will get a reply within 24 hours. Thanks.

Need more information?

Contact us for more details about our products and services.

Email

sales@baozt.com

WhatsApp

0086-17312373686

Leave Your Message

Leave Your Message