​SHL Series Double-Drum Water-Tube Chain Grate Boiler

SHL Series Double-Drum Water-Tube Chain Grate BoilerThe SHL series boiler is a new generation of high-capacity, field-assembled, coal-fired water-tube boiler, available for both st...


  • Evaporation Capacity: 20 - 75 t/h
  • Steam Pressure: 1.6 / 2.5 MPa
  • Thermal Efficiency: 81.2% - 82.77%
  • Effective Grate Area: 22.6 - 71.25 m²
  • Fuel: Class II Bituminous Coal

Description

Product Tags

SHL Series Double-Drum Water-Tube Chain Grate Boiler

The SHL series boiler is a new generation of high-capacity, field-assembled, coal-fired water-tube boiler, available for both steam and hot water generation. Developed through extensive research and collaboration with leading institutions, this series is engineered to meet national energy policies and the large-scale central heating demands of modern industries. It stands out for its high thermal efficiency, robust power output, and exceptional load adaptability. The sophisticated design ensures a high degree of operational automation, safety, and reliability.

Key Structural and Performance Features
  • Advanced Double-Drum Design: The boiler features a double-drum, horizontal layout with a natural circulation water-tube system. This structure optimizes heat transfer and ensures stable operation under varying loads.
  • High-Efficiency Combustion System: Equipped with a reliable chain grate stoker, the combustion system is designed for bituminous coal. It utilizes independent air chambers and dual-side air intake, allowing for precise combustion control. The rationalized design of the front and rear arches ensures complete fuel burnout and wide adaptability to different coal types.
  • Mechanized and Automated Operation: The entire system is engineered for mechanization, incorporating essential auxiliary equipment such as an economizer, air preheater, forced draft fan, induced draft fan, gearbox, and dust collection systems. This is complemented by a comprehensive electrical control panel with interlock protection and alarm systems for over-temperature and over-pressure, achieving a high level of automation.
  • Compact and Efficient Structure: Despite its large capacity, the overall structure is relatively compact. The efficient layout of heating surfaces, including the main furnace, superheater, and economizer, maximizes thermal efficiency while minimizing footprint.
Main Technical Parameters

The SHL series offers a wide range of models to suit diverse industrial needs. The detailed technical specifications are outlined in the table below, covering capacities from 20 to 75 t/h.

ItemSHL20-1.6-AII
SHL20-2.5-AII
SHL25-1.6-AII
SHL25-2.5-AII
SHL30-1.6-AII
SHL30-2.5-AII
SHL35-1.6-AII
SHL35-2.5-AII
SHL40-1.6-AII
SHL40-2.5-AII
SHL75-1.6-AII
SHL75-2.5-AII
Rated Steam Capacity (t/h)202530354075
Rated Pressure (MPa)1.6 / 2.5
Feedwater / Saturated Steam Temp (°C)104 / 204/226/400
Boiler Thermal Efficiency (%)82.7782.282.388282.481.2
Main Body Heating Surface (m²)458526.2550573.6610.91172.7
Superheater Area (m²)154157159176189365
Economizer Area (m²)446307.8307.8338359639.7
Air Preheater Area (m²)440557537588.6628.61158
Design Coal TypeII Class Bituminous Coal
Combustion MethodChain Grate Stoker
Effective Grate Area (m²)22.628.8530.132.535.171.25
Max Transport Height (mm)104501045010800108001080013500
Min Boiler Room Height (mm)113501135011750117501175015708
Overall Width (mm)422049705080545058209760
Overall Length (mm)4970571096959695969511950

Note: The product performance and technical parameters listed are subject to change. All specifications are finalized based on the official ex-factory technical documentation.

Company Strength & Qualifications

Modern Manufacturing Factory
Quality Certifications

INQUIRY

If you want to get a quotation or more product details, please leave us a message, You will get a reply within 24 hours. Thanks.

Need more information?

Contact us for more details about our products and services.

Email

sales@baozt.com

WhatsApp

0086-17312373686

Leave Your Message

Leave Your Message